![](https://www.emsyst.sk/wp-content/uploads/2024/05/EMS21.webp)
This version of the sensor has a built-in signal conditioner with a voltage or current output and a supply voltage of 5 / 24 V. The signal conditioner is fully integrated in the sensor body. Dimensions and parameters are identical to the EMS20 model. The output can be directly connected to a PLC or other measuring device with suitable inputs.
Note:
Due to the large number of possible combinations of force range, load direction and sensor output, it is complicated to keep them all in stock. Please inquire by email about the availability and delivery time of your chosen combination.
Supported outputs | |||
---|---|---|---|
Type | Supply voltage | Direction | Output |
Voltage | 5 VDC | Tension / Compression | 0.5 .. 4.5 V |
24 VDC | Tension / Compression | 2 .. 10 V | |
24 VDC | Tension and Compression | 2 .. 6 .. 10 V | |
Current | 24 VDC | Tension / Compression | 4 .. 20 mA |
24 VDC | Tension and Compression | 4 .. 12 .. 20 mA |
Weight | N/A |
---|---|
Dimensions | N/A |
Load direction | Compression, Tension, Tension and Compression |
Rated Capacity (Fn) | 100N, 200N, 500N, 1KN, 2KN, 5KN |
Output | 0,5 – 2,5 – 4,5 V (5 VDC), 0,5 – 4,5 V (5 VDC), 2 – 10 V (24 VDC), 2 – 6 – 10 V (24 VDC), 4 – 12 – 20 mA (24 VDC), 4 – 20 mA (24 VDC) |
Rated capacity (F.S.) | 0.1 / 0.2 / 0.5 / 1 / 2 / 5 kN |
Overload - Safe - Ultimate - Permanent static load - Dynamic load | 130% F.S. 150% F.S. 75% F.S. 50% F.S. |
Voltage output - Standard - With zero offset - Customer design | 2 .. 10 V 2 .. 6 .. 10 V 0.5 .. 10 |
Min. load impedance | 2 kΩ |
Current output - Standard - With zero offset - Custom design | 4 .. 20 mA 4 .. 12 .. 20 mA 1 ... 20 mA |
Max load impedance | 500 kΩ |
Supply voltage - Range - Current consumption (max) | 24 ± 10% VDC 40 mA |
Max error - Non-linearity - Hysteresis - Creep (30 min) | 0.25% F.S. 0.25% F.S. 0.1% F.S. |
Temperature effect - On zero - On output | 0.15% F.S./10°C 0.15% F.S./10°C |