This version of the sensor has a built-in signal conditioner with a voltage or current output and a supply voltage of 5 / 24 V. The signal conditioner is fully integrated in the sensor body. Dimensions and parameters are identical to the EMS20 model. The output can be directly connected to a PLC or other measuring device with suitable inputs.

Note:
Due to the large number of possible combinations of force range, load direction and sensor output, it is complicated to keep them all in stock. Please inquire by email about the availability and delivery time of your chosen combination.

Supported outputs
TypeSupply voltageDirectionOutput
Voltage5 VDCTension / Compression0.5 .. 4.5 V
24 VDCTension / Compression2 .. 10 V
24 VDCTension and Compression2 .. 6 .. 10 V
Current24 VDCTension / Compression4 .. 20 mA
24 VDCTension and Compression4 .. 12 .. 20 mA
WeightN/A
DimensionsN/A
Load direction

Compression, Tension, Tension and Compression

Rated Capacity (Fn)

100N, 200N, 500N, 1KN, 2KN, 5KN

Output

0,5 – 2,5 – 4,5 V (5 VDC), 0,5 – 4,5 V (5 VDC), 2 – 10 V (24 VDC), 2 – 6 – 10 V (24 VDC), 4 – 12 – 20 mA (24 VDC), 4 – 20 mA (24 VDC)

Datasheet EMS21 - SK Download.pdf
Datasheet EMS21 - ENDownload.pdf
Model EMS20 / EMS21 - 100N, 200N, 500N Download.stp
Model EMS20 / EMS21 - 1kN, 2kN, 5kN Download.stp
Rated capacity (F.S.)0.1 / 0.2 / 0.5 / 1 / 2 / 5 kN
Overload
- Safe
- Ultimate
- Permanent static load
- Dynamic load

130% F.S.
150% F.S.
75% F.S.
50% F.S.
Voltage output
- Standard
- With zero offset
- Customer design

2 .. 10 V
2 .. 6 .. 10 V
0.5 .. 10
Min. load impedance2 kΩ
Current output
- Standard
- With zero offset
- Custom design

4 .. 20 mA
4 .. 12 .. 20 mA
1 ... 20 mA
Max load impedance500 kΩ
Supply voltage
- Range
- Current consumption (max)

24 ± 10% VDC
40 mA
Max error
- Non-linearity
- Hysteresis
- Creep (30 min)

0.25% F.S.
0.25% F.S.
0.1% F.S.
Temperature effect
- On zero
- On output

0.15% F.S./10°C
0.15% F.S./10°C