Load Cells Signal Conditioner
Input: max. 4 Load Cells
Outputs: 0 ... ± 10 V, 4 ... 20 mA and other
Power Supply: 24 VDC
Adjustable electronic filter, DIN rail mounting.
Accuracy class | 0.1 |
Span adjustment | 0.2 ... 4.5 mV/V |
Zero adjustment | ± 10 % FSO |
Excitation - voltage - sensor min. impedance - current - sensor max. impedance |
5/10 VDC 82 Ω 10/20/40 mA 1000/375/63 Ω |
Amplifier - gain - input offset voltage drift - thermal sensitivity drigt - non-linearity |
440 ... 10000 1 μV/°C 150 ppm/°C 0.05% |
Active filter - Butterworth 2nd order - max. freq. range - min. freq. range |
4 kHz 3 Hz |
Output voltage - range - min. load impedance |
±10 V 2 kΩ |
Output current - range - max. load impedance |
4 ... 20 mA 600 Ω |
Power Supply - range - max. current sonsumption (4 sensors) |
24 VDC ± 15 % 200 mA |
Temperature range - operating - storage |
-10 ... +50 °C -40 ... +85 °C |
Protection | IP20 |