Rated Capacity (Mn) | 10, 20, 50, 100, 200, 500 | Nm |
---|---|---|
Overload - Safe - Ultimate - Permanent Static Load - Dynamic Load |
130 150 75 50 |
% Mn % Mn % Mn % Mn |
Nominal Sensitivty Cn (± 2%) | 1.5 | mV/V |
Zero balance | ± 0.03 | mV/V |
Max Error - Non-linearity - Hysteresis - Creep (30 min) |
0.25 0.25 0.1 |
% F.S. % F.S. % F.S. |
Temperature Effect - On Zero - On Output |
0.1 0.1 |
% F.S./10 °C % F.S./10 °C |
Bridge Resistance Range 10, 20, 50 Nm - Input Resistance - Output Resistance Range 100, 200, 500 Nm - Input Resistance - Output Resistance |
390 ± 20 350 ± 10 375 ± 20 350 ± 10 |
Ω Ω Ω Ω |
Insulation Impedance | > 500 | MΩ |
Excitation - Recommended - Maximal |
7 ... 10 15 |
V V |
Temperature Range - Compensated - Operating |
0 ... +50 -10 ... +70 |
°C °C |
Protection | IP54 | |
Cable - Type - Length |
LifYDY 4x0.14 2 |
m |
Sensor Body Material - Range 10, 20, 50 Nm - Range 100, 200, 500 Nm |
Aluminium Staineless Steel |
|
Sencor Cover Material | Aluminium |